Scanning of flat textile-based radiation dosimeters: Influence of parameters on the quality of results

Description

Flat woven polyamide textiles were chosen for modification with nitro blue tetrazolium chloride (NBT) or 2,3,5-triphenyltetrazolium chloride (TTC). Such samples change colour from white to blue (NBT) or red (TTC) if exposed to ionizing radiation or UV light. When inhomogenously irradiated, a clear pattern of the absorbed dose distribution is visible to the naked eye. Performance of quantitative 2D analysis with the aid of a flat-bed document scanner was proposed. Most importantly, the application of a scanner is an easy method for the assessment of irradiated samples. Therefore, scanning parameters such as resolution, sharpness, scanning reproducibility and sample preparation were assessed in this work; and optimal parameters were chosen. The cause of uncertainty in the measurements is discussed. - Highlights: • 2D textile dosimetry analysis with the aid of a flat-bed scanner is shown. • Scanning parameters and reproducibility were assessed in this work. • Optimal scanning parameters were chosen. • Cause of uncertainty in the measurements is discussed

Availability note (English)

Available from http://dx.doi.org/10.1016/j.radmeas.2013.08.011

Additional details

Identifiers

DOI
10.1016/j.radmeas.2013.08.011;
PII
S1350-4487(13)00339-9;

Publishing Information

Journal Title
Radiation Measurements
Journal Volume
58
Journal Page Range
p. 87-93
ISSN
1350-4487
CODEN
RMEAEP

Optional Information

Copyright
Copyright (c) 2013 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved.