Published March 2015 | Version v1
Journal article

A study of cavitating and non-cavitating performances of valveless micropump through dynamic measurement of chamber pressure

  • 1. Optical-Bio Microsystems Laboratory, Department of Mechanical Engineering, Concordia University, EV-13-235 1515 St. Catherine (O), Montreal (Canada)

Description

A lot of work has gone into the study of valveless micropumps for various applications. However, the complex fluid-structure interactional physics and associated phenomena such as cavitation affects the characterization of valveless micropumps, for applying them reliably in any real-time applications. This paper presents a method of characterization of valveless micropump performance through dynamic measurement of chamber pressure. Experimental investigation has been carried out to study the micropump behavior through pressure measurement under both cavitation and non-cavitation conditions, and the results show that this technique is useful for the characterization of micropump. (paper)

Availability note (English)

Available from http://dx.doi.org/10.1088/0960-1317/25/3/035006

Additional details

Publishing Information

Journal Title
Journal of Micromechanics and Microengineering. Structures, Devices and Systems
Journal Volume
25
Journal Issue
3
Journal Page Range
[12 p.]
ISSN
0960-1317
CODEN
JMMIEZ

INIS

Country of Publication
United Kingdom
Country of Input or Organization
International Atomic Energy Agency (IAEA)
INIS RN
47061543
Subject category
S42: ENGINEERING;
Descriptors DEI
CAVITATION; PERFORMANCE; PRESSURE MEASUREMENT; PUMPS; REAL TIME SYSTEMS; RELIABILITY
Descriptors DEC
EQUIPMENT