Published 2020 | Version v1
Journal article

Estimation of kinetics parameters by Monte Carlo fixed-source calculations for point kinetic analysis of accelerator-driven system

  • 1. Nuclear Engineering Department, Seoul National University, Seoul (Korea, Republic of)
  • 2. Kyoto University, Institute for Integrated Radiation and Nuclear Science, Kumatori, Osaka (Japan)

Description

The point kinetics model for an initially subcritical system such as the accelerator-driven system (ADS) requires the adjoint-weighted kinetics parameters to be estimated in its reference subcritical state with external sources. Monte Carlo (MC) algorithms are newly developed to calculate the kinetics parameters weighted by the adjoint function, which is the solution to the inhomogeneous adjoint equation, in the MC fixed-source mode calculations. The developed algorithm is verified through a simple two-group problem by comparing with analytic solutions. The one-point kinetics analyses using the estimated kinetics parameters are applied for beam trip transient problems and a control rod drop experiment in ADS at the Kyoto University Critical Assembly. (author)

Availability note (English)

Available from https://doi.org/10.1080/00223131.2019.1699188

Additional details

Publishing Information

Journal Title
Journal of Nuclear Science and Technology (Tokyo) (Online)
Journal Volume
57
Journal Issue
2
Journal Page Range
p. 177-186
ISSN
1881-1248

Optional Information

Notes
30 refs., 6 figs., 4 tabs.