Method for consequence calculations for severe accidents

Description

This report was commissioned by the Swedish State Power Board, who wanted a method for calculation of radiation doses in the surroundings of nuclear power plants caused by severe accidents. The PLUCON4 code were used for the calculations. A TC-SV-accident at Ringhals 1 wer chosen as example. A transient without shutdown leads to core meltdown through the reactor vessel. The pressure peak at the moment of vessel failure opens a safety valve in the dry well. Meteorolgical data for two years from the Ringhals meteorological tower were analysed to find representative weather situations. As typical weather were chosen Pasquill D with wind speed 8 m/s, and as extreme weather were chosen Pasquill F with wind speed 4.8 m/s. (author)

Availability note (English)

MF available from INIS under the Report Number; Also available from Risoe Library, DK-4000 Roskilde, Denmark.

Files

Restricted

The record is publicly accessible, but files are restricted to users with access.

Additional details

Additional titles

Subtitle (English)
Transient accident with safety valve at Ringhals 1
Original title (Danish)
Metode for konsekvensberegninger for store havarier
Original subtitle (Danish)
Transient-uheld med sikkerhedsventil paa Ringhals I.

Publishing Information

ISBN
87-550-1253-1
Imprint Pagination
63 p.
Report number
RISO-M--2598