Published 1994 | Version v1
Report Open

Estimating an appropriate sampling frequency for monitoring ground water well contamination

  • 1. Westinghouse Savannah River Co., Aiken, SC (United States). Applied Statistics Group

Description

Nearly 1,500 ground water wells at the Savannah River Site (SRS) are sampled quarterly to monitor contamination by radionuclides and other hazardous constituents from nearby waste sites. Some 10,000 water samples were collected in 1993 at a laboratory analysis cost of $10,000,000. No widely accepted statistical method has been developed, to date, for estimating a technically defensible ground water sampling frequency consistent and compliant with federal regulations. Such a method is presented here based on the concept of statistical independence among successively measured contaminant concentrations in time

Availability note (English)

MF available from INIS under the Report Number; Also available from OSTI as DE94017806; NTIS; US Govt. Printing Office Dep.

Files

26010521.pdf

Files (786.9 kB)

Name Size Download all
md5:14fde1511dd31798d4e30dc0c0a7c97c
786.9 kB Preview Download

Additional details

Publishing Information

Imprint Pagination
6 p.
Report number
WSRC-MS--94-0111

Conference

Title
Institute of Nuclear Materials Management annual meeting.
Dates
17-20 Jul 1994.
Place
Naples, FL (United States).

Optional Information

Contract/Grant/Project number
Contract AC09-89SR18035
Funding organization
USDOE, Washington, DC (United States).
Secondary number(s)
CONF-940748--87.