We continue the study of micro channel plates (MCP) as the active element of a shower maximum (SM) detector. We present below test beam results obtained with MCPs detecting directly secondary particles of an electromagnetic shower. The MCP efficiency to shower particles is close to 100%. The time resolution obtained for this new type of the SM detector is at the level of 40 ps

Availability note (English)

Available from http://dx.doi.org/10.1016/j.nima.2015.05.029

Additional details

Identifiers

DOI
10.1016/j.nima.2015.05.029;
PII
S0168-9002(15)00661-0;

Publishing Information

Journal Title
Nuclear Instruments and Methods in Physics Research. Section A, Accelerators, Spectrometers, Detectors and Associated Equipment
Journal Volume
795
Journal Page Range
p. 52-57
ISSN
0168-9002
CODEN
NIMAER

INIS

Country of Publication
Netherlands
Country of Input or Organization
International Atomic Energy Agency (IAEA)
INIS RN
47030636
Subject category
S46: INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY;
Descriptors DEI
BEAMS; EFFICIENCY; MICROCHANNEL ELECTRON MULTIPLIERS; SHOWERS; TIME RESOLUTION
Descriptors DEC
ELECTRON MULTIPLIERS; ELECTRON TUBES; RESOLUTION; TIMING PROPERTIES

Optional Information

Copyright
Copyright (c) 2015 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved.