Measurement of the exposure rate due to low energy x-rays emitted from video display terminals
Description
Thermoluminescent dosimeters of CaSO4:Dy have been used to measure the low energy x-rays emitted from Video Display Terminals (VDTs). For each terminal, three points were measured with five dosimeters at each point. The points were at distances of 5 and 50 cm in front of the screen and at 65 cm with an angle of approximately 500. The last two positions approximate to positions of the lenses of the eye and the gonads respectively. A survey of 50 VDTs at a distance of 5 cm from the screen resulted in exposure rates nearly fifteen times below the exposure rate of 0.5 mR h-1 (0.129 μC kg-1 h-1) which is the limit recommended by the International Atomic Energy Agency (IAEA), Safety Series No. 9 (1967) Basic Safety Standards for Radiation Protection. (author)
Additional details
Publishing Information
- Journal Title
- Appl. Radiat. Isot.
- Journal Volume
- 39
- Journal Issue
- 2
- Series
- Appl. Radiat. Isot.
- Journal Page Range
- 173-174
- CODEN
- ARISE
INIS
- Country of Publication
- United Kingdom
- Country of Input or Organization
- United Kingdom
- INIS RN
- 19044958
- Subject category
- S61: RADIATION PROTECTION AND DOSIMETRY;
- Descriptors DEI
- DISPLAY DEVICES; DOSE LIMITS; EYES; GONADS; RADIATION DOSES; SAFETY STANDARDS; THERMOLUMINESCENT DOSEMETERS; X RADIATION
- Descriptors DEC
- BODY; COMPUTER-GRAPHICS DEVICES; DOSEMETERS; ELECTROMAGNETIC RADIATION; IONIZING RADIATIONS; LUMINESCENT DOSEMETERS; MEASURING INSTRUMENTS; ORGANS; RADIATIONS; SENSE ORGANS