Published 1988 | Version v1
Journal article

Measurement of the exposure rate due to low energy x-rays emitted from video display terminals

Creators

  • 1. Instituto de Pesquisas Energeticas e Nucleares, Sao Paulo (Brazil)

Description

Thermoluminescent dosimeters of CaSO4:Dy have been used to measure the low energy x-rays emitted from Video Display Terminals (VDTs). For each terminal, three points were measured with five dosimeters at each point. The points were at distances of 5 and 50 cm in front of the screen and at 65 cm with an angle of approximately 500. The last two positions approximate to positions of the lenses of the eye and the gonads respectively. A survey of 50 VDTs at a distance of 5 cm from the screen resulted in exposure rates nearly fifteen times below the exposure rate of 0.5 mR h-1 (0.129 μC kg-1 h-1) which is the limit recommended by the International Atomic Energy Agency (IAEA), Safety Series No. 9 (1967) Basic Safety Standards for Radiation Protection. (author)

Additional details

Publishing Information

Journal Title
Appl. Radiat. Isot.
Journal Volume
39
Journal Issue
2
Series
Appl. Radiat. Isot.
Journal Page Range
173-174
CODEN
ARISE