An extended role for thermoluminescent phosphors in personnel, environmental and accident dosimetry using sensitisation, re-estimation and fast fading

Creators

  • 1. Central Electricity Generating Board, Berkeley (UK). Berkeley Nuclear Labs.

Description

This paper summarises some techniques for extending the usefulness of conventional phosphors in personnel, environmental and accident dosimetry. An optimised procedure for utilising radiation sensitisation and UV re-estimation in thermoluminescent LiF is presented. In particular it is shown that optimum performance is achieved by using a UV wavelength of 250 +- 10 nm for both the UV/thermal anneal following sensitisation, and for the UV re-estimation procedure. In the case of Harshaw Lif Chips (3x3x0.9 mm3) the sensitivity is increased by a factor of 4-5 to achieve a minimum detectable dose of approx.=10 μGy (2sigma) and a minimum re-estimable dose of 50-100 mGy (2sigma), dependent on batch. Sensitized LiF also exhibits improved tissue equivalence, extended linearity and improved precision at low doses. The information from fast-fading glow peaks, which is normally rejected, is shown to have a useful application to the evaluation of short-term increases in environmental dose rates such as may occur following accidental releases of radioactivity. (orig.)

Additional details

Publishing Information

Journal Title
Nucl. Instrum. Methods Phys. Res.
Journal Volume
206
Journal Issue
1/2
Series
Nucl. Instrum. Methods Phys. Res.
Journal Page Range
239-242
ISSN
0029-554X