A time selector intended for researching time distribution of the events started by some initial event is described. The device is made in a CAMAC module of a unit width and is controlled from the DATAWAY crate. The number of channels is changed from 8 to 1024; duration of the channel is from 1 to 128 (μs); the number of measurement cycles is from 1 to 128. Information is transferred from the module to the DATAWAY in ULS data block mode. The generator is stabilized by quartz
Files
19041968.pdf
Files
(185.0 kB)
| Name | Size | Download all |
|---|---|---|
|
md5:382c801bcaf5a7fb6ccb18d370f9a3a9
|
185.0 kB | Preview Download |
System files
(21.5 kB)
| Name | Size | Download all |
|---|
Additional details
Additional titles
- Original title (Russian)
- Временной селектор
Publishing Information
- Imprint Pagination
- 6 p.
- Report number
- JINR--13-87-250
INIS
- Country of Publication
- USSR
- Country of Input or Organization
- USSR
- INIS RN
- 19041968
- Subject category
- S46: INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY;
- Descriptors DEI
- CAMAC SYSTEM; DATA PROCESSING; FLOWSHEETS; MULTI-CHANNEL ANALYZERS; NUCLEAR INSTRUMENT MODULES; RADIATION DETECTORS; TIMING CIRCUITS
- Descriptors DEC
- DIAGRAMS; ELECTRONIC CIRCUITS; ELECTRONIC EQUIPMENT; EQUIPMENT; INFORMATION; MEASURING INSTRUMENTS; PULSE ANALYZERS
Optional Information
- Notes