Published 1993
| Version v1
Book
RELAP5/MOD2 analysis of the station blackout experiment SP-ST-01, performed in SPES facility
Description
SPES integral test facility is a scale model of a commercial three-loop PWR plant, allowing the simulation of a wide range of accident scenarios. A loss of on/off site power test was carried out on this facility in November 1989, with the aim of investigating the effects induced in the primary system by the application of a ''bleed and feed'' procedure. This test, planned in the frame of the ENEA-NRC cooperation on Accident Management Program, was included in the test matrix of the International Code Assessment Program for validation of RELAP5/Mod.2 code. This paper presents a survey of the results of the post-test calculations performed with the above mentioned code
Additional details
Publishing Information
- Publisher
- American Society of Mechanical Engineers.
- Imprint Place
- New York, NY (United States)
- ISBN
- 0-7918-0636-7
- Imprint Title
- 2nd ASME-JSME international conference on nuclear engineering -- 1993
- Imprint Pagination
- 770 p.
- Journal Page Range
- p. 237-246.
Conference
- Title
- 2. Japan Society of Mechanical Engineers (JSME)/American Society of Mechanical Engineers (ASME) joint international conference on nuclear engineering.
- Dates
- 21-24 Mar 1993.
- Place
- San Francisco, CA (United States).
INIS
- Country of Publication
- United States
- Country of Input or Organization
- United States
- INIS RN
- 25058805
- Subject category
- S21: SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS;
- Resource subtype / Literary indicator
- Conference, Numerical Data
- Descriptors DEI
- COMPUTER CALCULATIONS; DEPRESSURIZATION; EXPERIMENTAL DATA; OUTAGES; PWR TYPE REACTORS; R CODES; REACTOR ACCIDENTS; REACTOR SAFETY EXPERIMENTS; TEST FACILITIES; THEORETICAL DATA
- Descriptors DEC
- ACCIDENTS; COMPUTER CODES; DATA; ENRICHED URANIUM REACTORS; INFORMATION; NUMERICAL DATA; POWER REACTORS; REACTORS; THERMAL REACTORS; WATER COOLED REACTORS; WATER MODERATED REACTORS
Optional Information
- Secondary number(s)
- CONF-930352--.