Evaluation of a new Spin-echo diffusion-weighted sequence on a 0.35 T open magnetic resonance imaging (MRI)-system: first experiences within 3 h after acute stroke
Creators
- 1. Klinikum Augsburg, Clinic for Diagnostic Radiology and Neuroradiology, Augsburg (Germany)
- 2. Klinikum Augsburg, Clinic for Neurology, Augsburg (Germany)
- 3. Toshiba America MRI Inc, Research and Development, South San Francisco, CA (United States)
Description
In acute stroke, diffusion-weighted magnetic resonance imaging helps to select patients who are eligible for thrombolysis, but is almost exclusively implemented on closed-bore scanners, which make monitoring of patients difficult. We developed and tested a cardiac gated Spin-echo diffusion-weighted sequence with prescan finetrim and motion correction on an open system with 0.35 T. Nineteen stroke patients appropriate for thrombolytic therapy by clinical criteria were enrolled in a prospective study on an intention-to-treat basis. In all but one patient, computed tomography and magnetic resonance imaging including the new diffusion-weighted sequence were performed within 3 h after symptom onset. Images were evaluated for acute cerebral ischemia and hemorrhage by two radiologists blinded to clinical information. Magnetic resonance imaging required a mean total acquisition time of 26 min. Sensitivity for early infarction was 94% in diffusion-weighted imaging and 73% in computed tomography. Six patients were excluded from thrombolysis due to an infarct size of more than 1/3 of the territory of the middle cerebral artery exclusively diagnosed with diffusion-weighted imaging. Hemorrhage was recognised by both, magnetic resonance imaging and computed tomography. We conclude that in acute stroke, diffusion-weighted imaging with an open system at 0.35 T is practicable. The implemented sequence reliably demonstrated the size of the infarction and improved the selection of patients who are eligible for thrombolysis. (orig.)
Availability note (English)
Available from: http://dx.doi.org/10.1007/s00234-005-1393-5Additional details
Identifiers
Publishing Information
- Journal Title
- Neuroradiology
- Journal Volume
- 47
- Journal Issue
- 7
- Journal Page Range
- p. 532-538
- ISSN
- 0028-3940
- CODEN
- NRDYAB
INIS
- Country of Publication
- Germany
- Country of Input or Organization
- Germany
- INIS RN
- 36098386
- Subject category
- S62: RADIOLOGY AND NUCLEAR MEDICINE;
- Descriptors DEI
- BRAIN; COMPUTERIZED TOMOGRAPHY; ISCHEMIA; NMR IMAGING; SPIN ECHO; THROMBOPOIESIS; THROMBOSIS; VASCULAR DISEASES
- Descriptors DEC
- ANEMIAS; BLOOD FORMATION; BODY; CARDIOVASCULAR DISEASES; CENTRAL NERVOUS SYSTEM; DIAGNOSTIC TECHNIQUES; DISEASES; HEMIC DISEASES; NERVOUS SYSTEM; ORGANS; SYMPTOMS; TOMOGRAPHY; VASCULAR DISEASES