Published 1980 | Version v1
Miscellaneous

Development and improvement in accuracy and reproducibility of dosimetry systems for X-ray intercomparison, neutron and high level gamma irradiation

Description

Lyoluminescence measurements using the amino acid glutamine have shown that a practically linear dose curve from 1 kGy to 20 kGy (100 krad to 2 Mrad) can be obtained with a standard error of the data points of 2 or 3%. Variation in the environmental conditions during post-irradiation storage of the samples greatly influence the LL signal. Clear perspex samples stored under different conditions of relative humidity have also been used, the optical density indicating the radiation dose. (Auth.)

Additional details

Additional titles

Subtitle (English)
Project No. 84

Publishing Information

Imprint Title
Application of atomic energy in agriculture
Imprint Pagination
154 p.
Journal Page Range
p. 26-29.
Report number