Published November 1, 2012 | Version v1
Journal article

Prone Accelerated Partial Breast Irradiation After Breast-Conserving Surgery: Five-year Results of 100 Patients

  • 1. Department of Radiation Oncology, New York University School of Medicine and Langone Medical Center, New York, New York (United States)
  • 2. Department of Surgery, New York University School of Medicine and Langone Medical Center, New York, New York (United States)
  • 3. Division of Biostastistics, Department of Environmental Medicine, New York University School of Medicine and Langone Medical Center, New York, New York (United States)

Description

Purpose: To report the 5-year results of a prospective trial of three-dimensional conformal external beam radiotherapy (3D-CRT) to deliver accelerated partial breast irradiation in the prone position. Methods and Materials: Postmenopausal patients with Stage I breast cancer with nonpalpable tumors <2 cm, negative margins and negative nodes, positive hormone receptors, and no extensive intraductal component were eligible. The trial was offered only after eligible patients had refused to undergo standard whole-breast radiotherapy. Patients were simulated and treated on a dedicated table for prone setup. 3D-CRT was delivered at a dose of 30 Gy in five 6-Gy/day fractions over 10 days with port film verification at each treatment. Rates of ipsilateral breast failure, ipsilateral nodal failure, contralateral breast failure, and distant failure were estimated using the cumulative incidence method. Rates of disease-free, overall, and cancer-specific survival were recorded. Results: One hundred patients were enrolled in this institutional review board-approved prospective trial, one with bilateral breast cancer. One patient withdrew consent after simulation, and another patient elected to interrupt radiotherapy after receiving two treatments. Ninety-eight patients were evaluable for toxicity, and, in 1 case, both breasts were treated with partial breast irradiation. Median patient age was 68 years (range, 53–88 years); in 55% of patients the tumor size was <1 cm. All patients had hormone receptor-positive cancers: 87% of patients underwent adjuvant antihormone therapy. At a median follow-up of 64 months (range, 2–125 months), there was one local recurrence (1% ipsilateral breast failure) and one contralateral breast cancer (1% contralateral breast failure). There were no deaths due to breast cancer by 5 years. Grade 3 late toxicities occurred in 2 patients (one breast edema, one transient breast pain). Cosmesis was rated good/excellent in 89% of patients with at least 36 months follow-up. Conclusions: Five-year efficacy and toxicity of 3D-CRT delivered in prone partial breast irradiation are comparable to other experiences with similar follow-up.

Availability note (English)

Available from http://dx.doi.org/10.1016/j.ijrobp.2012.01.039

Additional details

Identifiers

DOI
10.1016/j.ijrobp.2012.01.039;
PII
S0360-3016(12)00083-1;

Publishing Information

Journal Title
International Journal of Radiation Oncology, Biology and Physics
Journal Volume
84
Journal Issue
3
Journal Page Range
p. 606-611
ISSN
0360-3016
CODEN
IOBPD3

INIS

Country of Publication
United States
Country of Input or Organization
International Atomic Energy Agency (IAEA)
INIS RN
44104226
Subject category
S62: RADIOLOGY AND NUCLEAR MEDICINE;
Descriptors DEI
DEATH; EDEMA; FILMS; HORMONES; IRRADIATION; MAMMARY GLANDS; NEOPLASMS; PAIN; PATIENTS; RADIATION DOSES; RADIOTHERAPY; SIMULATION; STANDARDS; SURGERY; TOXICITY; VERIFICATION
Descriptors DEC
BODY; DISEASES; DOSES; GLANDS; MEDICINE; NUCLEAR MEDICINE; ORGANS; PATHOLOGICAL CHANGES; RADIOLOGY; SYMPTOMS; THERAPY

Optional Information

Copyright
Copyright (c) 2012 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved.