Published December 11, 2012 | Version v1
Journal article

Single photon avalanche diode radiation tests

  • 1. Czech Technical University in Prague, Brehova 7, 115 19 Prague 1 (Czech Republic)
  • 2. NASA Goddard Space Flight Center, Mail Code 694, Greenbelt, MD 20771 (United States)

Description

The single photon counting diodes are recently planned for applications in deep space missions. That is why the proton radiation and gamma ray radiation tests of silicon based single photon avalanche diodes were measured and compared. The main characteristic that changed after the irradiation was effective dark count rate, which was measured using actively quenching and gating circuit. The radiation reached 6.5 krad at 53 MeV protons energy and 34 krad using gamma ray radiation source 60Co. The annealing rates were monitored at room temperature and at 60 °C.

Availability note (English)

Available from http://dx.doi.org/10.1016/j.nima.2011.11.001

Additional details

Identifiers

DOI
10.1016/j.nima.2011.11.001;
PII
S0168-9002(11)02034-1;

Publishing Information

Journal Title
Nuclear Instruments and Methods in Physics Research. Section A, Accelerators, Spectrometers, Detectors and Associated Equipment
Journal Volume
695
Journal Page Range
p. 309-312
ISSN
0168-9002
CODEN
NIMAER

Conference

Title
6. international conference on new developments in protodetection
Acronym
NDIP11
Dates
4-8 Jul 2011
Place
Lyon (France)

Optional Information

Copyright
Copyright (c) 2011 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved.