Development of a radioimmunoassay for measuring gonadotrophin releasing hormone in patients receiving treatment
- 1. Charing Cross and Westminster Medical School, Westminster, London (UK)
- 2. West Middlesex Univ. Hospital, Isleworth (UK)
- 3. Royal Free Hospital, London (UK)
Description
This gonadotrophin releasing hormone (GnRH) assay showed good precision, recovery, and parallelism over a wide range of GnRH concentrations with a sensitivity of 15 pg/ml. The assay was compared with a commercially available kit (Buhlmann Laboratories). Although the Buhlmann kit showed acceptable precision, recovery, sensitivity, and correlation with the developed GnRH assay for plasma samples, lack of parallelism of serially diluted plasma and urine samples was consistently observed, together with poor correlation with the developed GnRH assay for urine, suggesting a matrix effect with the Buhlmann kit. The developed assay is suitable for measuring GnRH in samples obtained from patients receiving pulsatile infusions of GnRH. In contrast, the commercially available Buhlmann kit was unsuitable for measuring plasma GnRH as the kit had a top standard of only 160 pg/ml, well below peak plasma concentration. It would not be possible to dilute samples for analysis because of lack of parallelism of diluted samples compared with standards obtained with the Buhlmann assay. (author)
Additional details
Publishing Information
- Journal Title
- Journal of Clinical Pathology
- Journal Volume
- 42
- Journal Issue
- 5
- Series
- J. Clin. Pathol.
- Journal Page Range
- 542-547
- ISSN
- 0021-9746
- CODEN
- JCPAA
INIS
- Country of Publication
- United Kingdom
- Country of Input or Organization
- United Kingdom
- INIS RN
- 21014432
- Subject category
- S62: RADIOLOGY AND NUCLEAR MEDICINE;
- Descriptors DEI
- GONADOTROPINS; HYPOTHALAMUS; PITUITARY GLAND; RADIOIMMUNOASSAY
- Descriptors DEC
- BODY; BRAIN; CENTRAL NERVOUS SYSTEM; ENDOCRINE GLANDS; GLANDS; HORMONES; IMMUNOASSAY; ISOTOPE APPLICATIONS; NERVOUS SYSTEM; ORGANS; PEPTIDE HORMONES; PITUITARY HORMONES; TRACER TECHNIQUES