Description

From the ECR plasma, hot electrons leak across the magnetic lines of force and by striking the plasma chamber produce bremsstrahlung x-rays. The wall bremsstrahlung gives information on the confinement status of hot electron. In our studies, experimental measurements are carried out in NANOGAN electron cyclotron resonance (ECR) ion source for the wall bremsstrahlung x-rays and the results are presented. While optimizing a particular charge state in ECR ion source, experimental parameters are adjusted to get a maximum current. The wall bremsstrahlung components are studied in these cases for understanding the hot electron confinement conditions

Additional details

Identifiers

Publishing Information

Journal Title
Review of Scientific Instruments
Journal Volume
79
Journal Issue
2
Journal Page Range
p. 02A324-02A324.3
ISSN
0034-6748
CODEN
RSINAK

Conference

Title
12. international conference on ion sources
Acronym
ICIS 2007
Dates
26-31 Aug 2007
Place
Jeju (Korea, Republic of)

Optional Information

Notes
(c) 2008 American Institute of Physics