A qualification of Kartini Water Coolant Reactor Based On Data By Flame Atomic Absorption Spectrometry (F-AAS) and Ion Selective Electrode (ISE) Methods

  • 1. Center for Accelerator Technology and Material Process, National Nuclear Energy Agency, Yogyakarta (Indonesia)

Description

A water coolant reactor represent one of product at reactor cooler system in nuclear reactor. Quality assurance of water coolant reactor needed to fulfilled of conditioned such as the content of Fe, Mn, Mg, Na, Cr, Ca and Cl elements in water coolant reactor < 1 ppm. The content of Fe, Mn, Mg, Na, Cr, and Ca elements in water coolant reactor were detected by flame atomic absorption spectrometry method, while the content of Cl- element was detected by ion selective electrode (ISE). The validation of AAS instrument were done by calibration of AAS instrument using solution of Cu 2 ppm and obtained of sensitivity and precision 0.019 ppm and precision 0.65 % respectively smaller than maximum permissible 0.4 ppm and 1 % respectively. The validation of ISE instrument showed that obtained of slope in the potential ring 0.56 - 0.59 mV. The content of Ca and Cl in ATR each 0.32 ± 0.005 ppm and 1.052 ± 0.009 ppm respectively, while the other elements such as Fe, Mn, Mg, Na, and Cr under the limit of detection. Based on the data show that quality of ATR fulfilled one of the qualifications of IAEA. (author)

Additional details

Additional titles

Original title (Indonesian)
Kualifikasi Air Tangki Reaktor (ATR) Kartini Berdasarkan Data Dukung Metoda Nyala Spektrometri Serapan Atom (SSA) dan Ion Selective Electode (ISE)

Publishing Information

Journal Title
Jurnal Iptek Nuklir
Journal Volume
11
Journal Issue
1
Journal Page Range
p. 17-21
ISSN
1410-6957

Optional Information

Notes
4 refs; 4 tabs