An 85 mm x 85 mm x 20 mm, 14 x 14 strip, planar germanium double sided strip detector (HpGeDSSD) has been used as a Compton Polarimeter to measure the linear polarization of photons emitted from aligned nuclei. Gamma rays following an alpha decay in the 227,228Th decay chains were used both for calibration of the device and for investigating the veracity of parity assignments based on systematic trends. An experimental arrangement of two interchangeable alpha detectors arranged 90 degrees apart allowed many systematic properties of the device to be investigated. Each of the pixels could be used both to scatter and absorb gamma rays, allowing high sensitivity (>60% of the Klein-Nishina formula) and high efficiency to be achieved. This combination yields a 'figure of merit' of unprecedented value. A description of the experiment and current status of data analysis will be presented and the potential future uses of this device will be discussed

Additional details

Identifiers

Publishing Information

Journal Title
AIP Conference Proceedings
Journal Volume
764
Journal Issue
1
Journal Page Range
p. 348-353
ISSN
0094-243X
CODEN
APCPCS

Conference

Title
Conference on nuclei at the limits
Dates
26-30 Jul 2004
Place
Argonne, IL (United States)

Optional Information

Notes
(c) 2005 American Institute of Physics