Published March 1976 | Version v1
Journal article

Spectrometric method of gamma detection in a multichannel flaw detector

  • 1. Tsentral'nyj Nauchno-Issledovatel'skij Inst. Chernoj Metallurgii, Moscow (USSR). Inst. Metallovedeniya i Fiziki Metallov

Description

The paper examines a spectrometric procedure of registration of γ-radiation in a scintillation detector. The procedure discussed makes it possible to achieve a multichannel registration in spatially separated beams of gamma-quanta by using a single photoelectron multiplier. We have determined the perturbations of the flow of the registered radiation caused by the overlapping of the amplitude spectra and the 'repumping' of the scattered radiation from one crystal into another. Taking these perturbations into account, we have obtained analytical expressions, establish the functional relation between the parameters of scintillation crystals, the performance of the photoelectron multiplier, the required value of the relative light yield of the sci ntillation crystals and the various physical and technological parameters of article control

Additional details

Additional titles

Original title (Russian)
Спектрометрическая методика регистрации гамма-излучения в многоканальном дефектоскопе

Publishing Information

Journal Title
Defektoskopiya
Journal Issue
no.2
Series
Defektoskopiya.

Optional Information

Notes
For English translation see the journal Sov. J. Nondestr. Test.