Published May 2000 | Version v1
Miscellaneous

Applicability of LBB(Leak-Before-Break) design for main steam line in nuclear power plant

Creators

  • 1. Korea Electric Power Research Institute, Taejon (Korea, Republic of)

Description

This report was reviewed the applicability of LBB (Leak-Before-Break) design for main steam line in the nuclear power plant based on the LBB design concept analysis procedure, results and standard design certification document. It is possible for us to apply LBB design for main steam line in nuclear power plant, in case of changing the material of MSL piping in direction of increasing the toughness and using leakage detection facilities which were reflected to foreign ALWR's

Part of:
Proceedings of the KNS spring meeting

Additional details

Publishing Information

Publisher
KNS
Imprint Place
Taejon (Korea, Republic of)
Imprint Title
Proceedings of the KNS spring meeting
Imprint Pagination
[CDROM]
Journal Page Range
[7 p.]

Conference

Title
2000 spring meeting of the KNS
Dates
26-27 May 2000
Place
Kori (Korea, Republic of)

INIS

Country of Publication
Korea, Republic of
Country of Input or Organization
Korea, Republic of
INIS RN
34027605
Subject category
S22: GENERAL STUDIES OF NUCLEAR REACTORS;
Resource subtype / Literary indicator
Conference, Non-conventional Literature
Descriptors DEI
DESIGN; DETECTION; LEAKS; NUCLEAR POWER PLANTS; STEAM LINES
Descriptors DEC
NUCLEAR FACILITIES; PIPELINES; POWER PLANTS; THERMAL POWER PLANTS

Optional Information

Notes
9 refs, 2 figs, 4 tabs