Published 2006 | Version v1
Miscellaneous

Statistical analysis of pit growth in CANDU steam generator tubes

  • 1. Babcock and Wilcox Canada Ltd., Cambridge, Ontario (Canada)
  • 2. Atomic Energy of Canada Limited, Mississauga, Ontario (Canada)

Description

During the outage of steam generators in a CANDU reactor unit, eddy current inspection detected volumetric indications (pitting) in the tubes at top-of-tubesheet region (TTS). The majority of the indications were found to be pre-existing pit-type defects based on a signal-to-signal analysis of previous inspection data. This investigation studies the pit growth by collecting individual pit size change from the data of two outages and calculating the growth rates and their confidence intervals. The pits at the TTS are divided into separate populations according to their locations and statistical test of homogeneity. The mean growth rate, 95% upper bound growth rate, and their confidence intervals of each population are evaluated using the bootstrap resampling method. A method is also proposed to lower the 95% upper bound growth rate by adjusting for the effect of the eddy current measurement error. (author)

Part of:
Fifth CNS international steam generator conference

Additional details

Publishing Information

Publisher
Canadian Nuclear Society
Imprint Place
Toronto, Ontario (Canada)
ISBN
0-919784-87-9
Imprint Title
Fifth CNS international steam generator conference
Imprint Pagination
248 Megabytes
Journal Page Range
[10 p.]

Conference

Title
5. CNS international steam generator conference. Proceedings
Dates
26-29 Nov 2006
Place
Toronto, Ontario (Canada)

Optional Information

Notes
Paper 2D003; 4 refs., 4 tabs., 8 figs.