Published November 2011 | Version v1
Journal article

Determination of the plasma parameters in the PF-3 facility by the methods of X-ray spectroscopy

  • 1. National Research Centre Kurchatov Institute (Russian Federation)

Description

NeIX and NeX spectra emitted by the PF-3 high-current (2 MA) plasma focus facility are measured. A numerical model describing the spectral intensities of the emission of helium- and hydrogen-like neon ions from an optically thick plasma is proposed. The electron temperature Te and electron density ne in the plasma of the PF-3 facility are determined by comparing the calculated and measured emission spectra of neon.

Additional details

Identifiers

Publishing Information

Journal Title
Plasma Physics Reports
Journal Volume
37
Journal Issue
11
Journal Page Range
p. 935-947
ISSN
1063-780X
CODEN
PPHREM

Optional Information

Copyright
Copyright (c) 2011 Pleiades Publishing, Ltd.