Description

Nuclear utilities worldwide have been upgrading their emergency core cooling system sump strainers to met new regulatory requirements for handling larger quantities of debris that might be generated during a loss of coolant accident. This paper presents briefly the background for the replacement of the existing strainers with a much larger filtering surface. Then it describes the modular design, the testing performed for its qualification, the manufacturing, the on-site installation and the commissioning of the strainers. Topics discussed include reduced-scale and large-scale testing, hydraulic and stress analyses, mechanical design, and descriptions of various installed designs. 30 retrofit strainer installations are currently underway in EDF's 900 MWe and 1300 MWe PWRs

Availability note (English)

Available from: SFEN, 5 rue des Morillons, 75015 Paris (France)

Additional details

Publishing Information

Imprint Pagination
9 p.
Report number
INIS-FR--08-1006

Conference

Title
ICAPP 2007 - International congress on advances in nuclear power plants. The nuclear renaissance at work
Dates
13-18 May 2007
Place
Nice Acropolis (France)

INIS

Country of Publication
France
Country of Input or Organization
France
INIS RN
39090727
Subject category
S21: SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS;
Resource subtype / Literary indicator
Conference, Non-conventional Literature
Descriptors DEI
DESIGN; ECCS; FEASIBILITY STUDIES; FOULING; MECHANICAL FILTERS; SPECIFICATIONS; TESTING
Descriptors DEC
ENGINEERED SAFETY SYSTEMS; FILTERS; REACTOR PROTECTION SYSTEMS

Optional Information

Notes
4 refs.