Published January 1, 2012 | Version v1
Journal article

Magnetic Resonance Lymphography–Guided Selective High-Dose Lymph Node Irradiation in Prostate Cancer

  • 1. Department of Radiation Oncology, Radboud University Nijmegen Medical Centre, Nijmegen (Netherlands)
  • 2. Department of Radiology, Radboud University Nijmegen Medical Centre, Nijmegen (Netherlands)
  • 3. Department of Urology, Radboud University Nijmegen Medical Centre, Nijmegen (Netherlands)

Description

Purpose: To demonstrate the feasibility of magnetic resonance lymphography (MRL) –guided delineation of a boost volume and an elective target volume for pelvic lymph node irradiation in patients with prostate cancer. The feasibility of irradiating these volumes with a high-dose boost to the MRL-positive lymph nodes in conjunction with irradiation of the prostate using intensity-modulated radiotherapy (IMRT) was also investigated. Methods and Materials: In 4 prostate cancer patients with a high risk of lymph node involvement but no enlarged lymph nodes on CT and/or MRI, MRL detected pathological lymph nodes in the pelvis. These lymph nodes were identified and delineated on a radiotherapy planning CT to create a boost volume. Based on the location of the MRL-positive lymph nodes, the standard elective pelvic target volume was individualized. An IMRT plan with a simultaneous integrated boost (SIB) was created with dose prescriptions of 42 Gy to the pelvic target volume, a boost to 60 Gy to the MRL-positive lymph nodes, and 72 Gy to the prostate. Results: All MRL-positive lymph nodes could be identified on the planning CT. This information could be used to delineate a boost volume and to individualize the pelvic target volume for elective irradiation. IMRT planning delivered highly acceptable radiotherapy plans with regard to the prescribed dose levels and the dose to the organs at risk (OARs). Conclusion: MRL can be used to select patients with limited lymph node involvement for pelvic radiotherapy. MRL-guided delineation of a boost volume and an elective pelvic target volume for selective high-dose lymph node irradiation with IMRT is feasible. Whether this approach will result in improved outcome for these patients needs to be investigated in further clinical studies.

Availability note (English)

Available from http://dx.doi.org/10.1016/j.ijrobp.2010.09.023

Additional details

Identifiers

DOI
10.1016/j.ijrobp.2010.09.023;
PII
S0360-3016(10)03331-6;

Publishing Information

Journal Title
International Journal of Radiation Oncology, Biology and Physics
Journal Volume
82
Journal Issue
1
Journal Page Range
p. 175-183
ISSN
0360-3016
CODEN
IOBPD3

INIS

Country of Publication
United States
Country of Input or Organization
International Atomic Energy Agency (IAEA)
INIS RN
44016312
Subject category
S62: RADIOLOGY AND NUCLEAR MEDICINE;
Descriptors DEI
HAZARDS; IRRADIATION; LYMPH NODES; MAGNETIC RESONANCE; NANOSTRUCTURES; NEOPLASMS; NMR IMAGING; PATIENTS; PELVIS; PLANNING; PROSTATE; RADIATION DOSES; RADIOTHERAPY; SUPERPARAMAGNETISM
Descriptors DEC
BODY; DIAGNOSTIC TECHNIQUES; DISEASES; DOSES; GLANDS; LYMPHATIC SYSTEM; MAGNETISM; MALE GENITALS; MEDICINE; NUCLEAR MEDICINE; ORGANS; RADIOLOGY; RESONANCE; THERAPY

Optional Information

Copyright
Copyright (c) 2012 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved.