Published 1979
| Version v1
Report
Open
Units for automation of signal timing matching
Description
A program-control pulse commutator and delay units in the CAMAC standard are described. They are intended for the time matching of signals coming from pulse shapers, photomultipliers, scintillation counters, etc. Delay units have been developed for automatic system for the accelerator check-out connected with the time matching of signals from different sources. The nanosecond pulse commutator is designed to facilitate different cheek-out, for instance, for a fast change of the event selection logic, for successive alignment of scintillation counters, etc
Availability note (English)
MF available from INIS under the Report Number.Files
12582434.pdf
Files
(239.7 kB)
| Name | Size | Download all |
|---|---|---|
|
md5:594a4a2bff24cfb2cdd934db181d7281
|
239.7 kB | Preview Download |
System files
(13.2 kB)
| Name | Size | Download all |
|---|
Additional details
Additional titles
- Original title (Russian)
- Блоки для автоматизации временного согласования сигналов
Publishing Information
- Imprint Pagination
- 8 p.
- Report number
- ITEF--94(1979)
INIS
- Country of Publication
- USSR
- Country of Input or Organization
- USSR
- INIS RN
- 12582434
- Subject category
- S46: INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY;
- Descriptors DEI
- CAMAC SYSTEM; DELAY CIRCUITS; FLOWSHEETS; SPECIFICATIONS; TRANSISTOR SWITCHING CIRCUITS
- Descriptors DEC
- DIAGRAMS; ELECTRONIC CIRCUITS; INFORMATION; SWITCHING CIRCUITS
Optional Information
- Notes
- 2 figs.