Published September 1, 2019 | Version v1
Journal article

Fast component re-emission in Xe-doped liquid argon

  • 1. Institute for Theoretical and Experimental Physics named by A.I. Alikhanov of National Research Centre "Kurchatov Institute", Moscow, 117218 (Russian Federation)
  • 2. National Research Nuclear University MEPhI (Moscow Engineering Physics Institute), Moscow 115409 (Russian Federation)

Description

We present the first direct experimental confirmation of the fast component re-emission in liquid argon (LAr) doped with xenon (Xe). This effect was studied at various Xe concentrations up to ∼3000 ppm. The rate constant of energy transfer for the fast component was quantified. It was shown that LAr doped with a high concentration of Xe without TPB has a better Pulse Shape Discrimination (PSD) efficiency than pure LAr or Xe-doped LAr with TPB. The stability of LAr+Xe mixture was tested for the first time at high Xe concentration for long continuous runtimes.

Availability note (English)

Available from http://dx.doi.org/10.1088/1748-0221/14/09/P09022

Additional details

Publishing Information

Journal Title
Journal of Instrumentation
Journal Volume
14
Journal Issue
09
Journal Page Range
p. P09022
ISSN
1748-0221