Published 1992 | Version v1
Book

Guideline values for skin decontamination measures based on nuclidspecific dose equivalent rate factors

  • 1. Badenwerk AG, Medical Dept., Karlsruhe (Germany)
  • 2. PreussenElektra, Medical Dept., Stade (Germany)

Description

Corresponding dose equivalent rate factors for various radionuclides are now available for determining the skin dose caused by skin contamination. These dose equivalent rate factors take into account all contributions from the types of radiation emitted. Any limits for skin decontamination measures are nowhere contained or determined yet. However, radiological protection does in practice require at least guideline values in order to prevent unsuitable or detrimental measures that can be noticed quite often. New calculations of dose equivalent rate factors for the skin now make the recommendation of guideline values possible. (author)

Part of:
8. International congress of the International Radiation Protection Association (IRPA8)

Additional details

Publishing Information

Publisher
International Radiation Protection Association
Imprint Place
Montreal, Quebec (Canada)
ISBN
1-55048-657-8
Imprint Title
8. International congress of the International Radiation Protection Association (IRPA8)
Imprint Pagination
2 v.
Journal Page Range
(v.2) p. 1754-1757

Conference

Title
8. international congress of the International Radiation Protection Association (IRPA8)
Dates
17-22 May 1992
Place
Montreal, Quebec (Canada)

INIS

Country of Publication
Canada
Country of Input or Organization
Canada
INIS RN
36056784
Subject category
S61: RADIATION PROTECTION AND DOSIMETRY; S62: RADIOLOGY AND NUCLEAR MEDICINE;
Resource subtype / Literary indicator
Conference
Descriptors DEI
CONTAMINATION; DOSE EQUIVALENTS; RADIATION PROTECTION; RADIOISOTOPES; SKIN ABSORPTION
Descriptors DEC
ABSORPTION; ISOTOPES; SORPTION; UPTAKE

Optional Information

Notes
7 refs.