A two multilayer X-ray mirror system has been developed to focus 8 keV X-rays from a synchrotron X-ray source. The system uses a Kirkpatrick-Baez mirror geometry and the mirrors are made by sputtering carbon and tungsten layers on spherical optical mirror substrates. A focused X-ray spot 40 μm wide by 10 μm high was obtained using an 8 keV X-ray beam from a wiggler beamline at the Stanford Synchrotron Radiation Laboratory. Similar mirror systems may be useful for microprobe and small sample experiments using both synchrotron and laboratory sources. (orig.)