Detection of cardiac wall motion defects with combined amplitude/phase analysis
- 1. National Institutes of Health, Bethesda, MD
Description
Fourier phase images have been used with some success to detect and quantify left ventricular (LV) wall motion defects. In abnormal regions of the LV, wall motion asynchronies often cause the time activity curve (TAC) to be shifted in phase. Such regional shifts are detected by analysis of the distribution function of phase values over the LV. However, not all wall motion defects result in detectable regional phase abnormalities. Such abnormalities may cause a reduction in the magnitude of contraction (and hence TAC amplitude) without any appreciable change in TAC shape(and hence phase). In an attempt to improve the sensitivity of the Fourier phase method for the detection of wall motion defects the authors analyzed the distribution function of Fourier amplitude as well as phase. 26 individuals with normal cardiac function and no history of cardiac disease served as controls. The goal was to detect and quantify wall motion as compared to the consensus of 3 independent observers viewing the scintigraphic cines. 26 subjects with coronary artery disease and mild wall motion defects (22 with normal EF) were studied ate rest. They found that analysis of the skew of thew amplitude distribution function improved the sensitivity for the detection of wall motion abnormalities at rest in the group from 65% to 85% (17/26 detected by phase alone, 22/26 by combined phase and amplitude analysis) while retaining a 0 false positive rate in the normal group. The authors conclude that analysis of Fourier amplitude distribution functions can significantly increase the sensitivity of phase imaging for detection of wall motion abnormalities
Additional details
Publishing Information
- Journal Title
- J. Nucl. Med.
- Journal Volume
- 26
- Journal Issue
- 5
- Series
- J. Nucl. Med.
- Journal Page Range
- 86
- ISSN
- 0022-3123
- CODEN
- JNMEA
Conference
- Title
- 32. annual meeting of the Society of Nuclear Medicine.
- Dates
- 2-5 Jun 1985.
- Place
- Houston, TX (USA).
INIS
- Country of Publication
- United States
- Country of Input or Organization
- United States
- INIS RN
- 19022440
- Subject category
- S62: RADIOLOGY AND NUCLEAR MEDICINE; S62: RADIOLOGY AND NUCLEAR MEDICINE;
- Resource subtype / Literary indicator
- Conference
- Descriptors DEI
- BLOOD FLOW; CARDIOGRAPHY; CARDIOVASCULAR DISEASES; DIAGNOSIS; DYNAMIC FUNCTION STUDIES; FOURIER ANALYSIS; HEART; IMAGE PROCESSING; MOTION; MYOCARDIUM; PHASE SHIFT; SCINTISCANNING; SENSITIVITY
- Descriptors DEC
- BODY; CARDIOVASCULAR SYSTEM; COUNTING TECHNIQUES; DIAGNOSTIC TECHNIQUES; DISEASES; MUSCLES; ORGANS; RADIOISOTOPE SCANNING
Optional Information
- Secondary number(s)
- CONF-850611--.