Hybrid Monte Carlo and deterministic simulation approach for modeling a computed radiography imaging chain from X-ray exposure to optical readout
Creators
- 1. Laboratoire Vibrations Acoustique (LVA) INSA Lyon, 25, Av. Jean Capelle, 69621 Villeurbanne Cedex (France)
- 2. Framatome / Intercontrôle 04, Rue Thomas Dumorey, 71100 Chalon sur Saone (France)
- 3. EDF – R&D, Département Matériaux et Mécanique des Composants, EDF LAB Les Renardières – ECUELLES, 77818 Moret-sur-Loing Cedex (France)
Description
Simulation of radiographic inspection is of great interest for experimental outcomes prediction and optimal operating condition determination. As concerns computed radiography (CR), the use of photo-stimulable imaging plates and laser scanners, implies modeling the behavior of a multi-stages detector. As a consequence, both the X-ray and the optical system responses have to be handled. Moreover, for high energy X-rays, two issues often trouble CR simulation: long running time and X-ray scattering image contribution, which should not be neglected. To overcome these issues, we have developed a complete hybrid model which is the first available one at such energies. In our approach, the imaging process is decomposed into three independent successive stages: X-ray attenuation by an object, X-ray latent image generation, and optical readout. A deterministic code is applied to obtain rapidly the transmitted X-ray image emerging from a complex object. The energy deposition is then simulated by a convolution of the transmitted X-ray image with a CR detector response model, which was obtained off-line by a Monte Carlo tool. Then, optical readout is modeled using the same hybrid approach, where the optical response (laser light spreading in the imaging plate) was obtained by Monte Carlo and laser scanning is modeled analytically. A good agreement has been observed between the proposed hybrid model and a full Monte Carlo approach for the X-ray energy deposition stage. A realistic X-ray inspection case study has been chosen to emphasize the interest of this complete hybrid model. The comparison of three different detector configurations and the influence of readout laser power are illustrated.
Additional details
Identifiers
- DOI
- 10.1016/j.nima.2019.06.069;
- PII
- S0168900219309143;
Publishing Information
- Journal Title
- Nuclear Instruments and Methods in Physics Research. Section A, Accelerators, Spectrometers, Detectors and Associated Equipment
- Journal Volume
- 941
- Journal Page Range
- vp.
- ISSN
- 0168-9002
- CODEN
- NIMAER
INIS
- Country of Publication
- Netherlands
- Country of Input or Organization
- International Atomic Energy Agency (IAEA)
- INIS RN
- 55016311
- Subject category
- S46: INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY;
- Descriptors DEI
- ATTENUATION; COMPUTERIZED SIMULATION; COMPUTERIZED TOMOGRAPHY; ENERGY ABSORPTION; ENERGY LOSSES; LASERS; LATENT IMAGES; MONTE CARLO METHOD; OPTICAL SYSTEMS; PLATES; READOUT SYSTEMS; X RADIATION; X-RAY DIFFRACTION
- Descriptors DEC
- ABSORPTION; CALCULATION METHODS; COHERENT SCATTERING; DIAGNOSTIC TECHNIQUES; DIFFRACTION; ELECTROMAGNETIC RADIATION; IONIZING RADIATIONS; LOSSES; RADIATIONS; SCATTERING; SIMULATION; SORPTION; TOMOGRAPHY
Optional Information
- Copyright
- Copyright (c) 2019 Elsevier B.V. All rights reserved.