Published 2009 | Version v1
Book

Raman distributed sensor system for temperature monitoring and leak detection in sodium circuits of FBR

Description

Leak detection in coolant loops of nuclear reactors is critical for the safety and performance of the reactors. The feasibility of using Raman distributed temperature sensor (RDTS) has been studied on a 30 m test loop. Temperature in sodium circuits of fast Breeder Reactor (FBR) exceeds 550 C degrees, gold coated fiber is chosen as sensor fibers. Leak is simulated through an artificial micro fissure integrated in the test loop with provision for controlled leak rate. The results are discussed in the paper. The temperature response of RDTS is compared to the conventional thermocouple and their performance was found comparable. The feasibility of detecting the temperature differential of a controlled leak with RDTS is demonstrated

Availability note (English)

Available from doi:

Additional details

Identifiers

Publishing Information

Publisher
IEEE - Institute of Electrical and Electronics Engineers
Imprint Place
New York (United States)
ISBN
978-1-4244-5207-1
Imprint Pagination
4 p.

Conference

Title
1. International Conference on Advancements in Nuclear Instrumentation, Measurement Methods and their Applications
Acronym
ANIMMA 2009
Dates
7-10 Jun 2009
Place
Marseille (France)

Optional Information

Notes
10 refs.