Published June 1983 | Version v1
Report

Contamination, contamination protection and contamination measurement during a steam generator revision in a power plant with a pressurized water reactor

Creators

  • 1. Reaktorwartungsdienst und Apparatebau G.m.b.H., Juelich (Germany, F.R.)

Description

For in-service eddy current inspection of steam generators, the inlet and outlet chambers must be opened on the primary side. The chambers must be entered several times for installation and removal of the test instruments or to seal a located defective tube. Inside the chambers, contamination and dose rates are high. Extensive measures and measurements are required to keep the personnel dose within the permissible range and to avoid incorporation, contamination of persons, and distribution of contaminants. The problems of workplace monitoring are discussed at length. (HP)

Abstract (German)

Bei der Wiederholungspruefung am DE mittels Wirbelstrom muessen primaerseitig die Ein- und Austrittskammern geoeffnet werden. Es sind mehrere Einstiege in die Kammern noetig, um die Pruefgeraete ein- und auszubauen, oder, falls ein defektes U-Rohr gefunden wird, dieses dicht zu verschliessen. In der Kammer herrschen hohe Dosisleistung und starke Kontamination. Umfangreiche Massnahmen und Messungen sind erforderlich, um die Personendosis in den vorgeschriebenen Grenzen zu halten und Inkorporation, Personenkontamination und Kontaminationsverschleppungen zu vermeiden. Die Problematik der Arbeitsplatzueberwachung wird naeher beschrieben. (HP)

Additional details

Additional titles

Original title (German)
Kontamination, Kontaminationsschutz und Kontaminationsmessung bei einer Dampferzeugerrevision in einem Kernkraftwerk mit Druckwasserreaktor

Publishing Information

Imprint Title
Radiation protection, measurements and methods
Imprint Pagination
615 p.
Journal Page Range
p. 277-280.
Report number
FS--83-30-T

Conference

Title
Radiation protection, measurements and methods.
Acronym
16. annual meeting of the Fachverband fuer Strahlenschutz e.V.
Dates
19-22 Oct 1982.
Place
Munich (Germany, F.R.).

Optional Information

Notes
Imprint:Strahlenschutzmesstechnik.;Tagungsbericht.
Secondary number(s)