SU-E-T-543: Measurement of Neutron Activation From Different High Energy Varian Linear Accelerators
- 1. University of Nevada, Las Vegas, Las Vegas, NV (United States)
- 2. Comprehensive Cancer Center of Nevada, Las Vegas, Nevada (United States)
Description
Purpose: Linear accelerators producing photons above 10 MeV may induce photonuclear reactions in high Z components of the accelerator. These liberated neutrons can then activate the structural components of the accelerator and other materials in the beam path through neutron capture reactions. The induced activity within the accelerator may contribute to additional dose to both patients and personnel. This project seeks to determine the total activity and activity per activated isotope following irradiation in different Varian accelerators at energies above 10 MeV. Methods: A Varian 21IX accelerator was used to irradiate a 30 cm × 30 cm × 20 cm solid water phantom with 15 MV x-rays. The phantom was placed at an SSD of 100 cm and at the center of a 20 cm × 20 cm field. Activation induced gamma spectra were acquired over a 5 minute interval after 1 and 15 minutes from completion of the irradiation. All measurements were made using a CANBERRA Falcon 5000 Portable HPGe detector. The majority of measurements were made in scattering geometry with the detector situated at 90° to the incident beam, 30 cm from the side of the phantom and approximately 10 cm from the top. A 5 minute background count was acquired and automatically subtracted from all subsequent measurements. Photon spectra were acquired for both open and MLC fields. Results: Based on spectral signatures, nuclides have been identified and their activities calculated for both open and MLC fields. Preliminary analyses suggest that activities from the activation products in the microcurie range. Conclusion: Activation isotopes have been identified and their relative activities determined. These activities are only gross estimates since efficiencies have not been determined for this source-detector geometry. Current efforts are focused on accurate determination of detector efficiencies using Monte Carlo calculations
Additional details
Identifiers
- DOI
- 10.1118/1.4924905;
Publishing Information
- Journal Title
- Medical Physics
- Journal Volume
- 42
- Journal Issue
- 6
- Journal Page Range
- vp.
- ISSN
- 0094-2405
- CODEN
- MPHYA6
INIS
- Country of Publication
- United States
- Country of Input or Organization
- International Atomic Energy Agency (IAEA)
- INIS RN
- 47066464
- Subject category
- S61: RADIATION PROTECTION AND DOSIMETRY;
- Descriptors DEI
- GAMMA SPECTRA; HIGH-PURITY GE DETECTORS; IRRADIATION; ISOTOPES; LINEAR ACCELERATORS; MEV RANGE 01-10; MONTE CARLO METHOD; NEUTRON REACTIONS; PHANTOMS; X RADIATION
- Descriptors DEC
- ACCELERATORS; BARYON REACTIONS; CALCULATION METHODS; ELECTROMAGNETIC RADIATION; ENERGY RANGE; GE SEMICONDUCTOR DETECTORS; HADRON REACTIONS; IONIZING RADIATIONS; MEASURING INSTRUMENTS; MEV RANGE; MOCKUP; NUCLEAR REACTIONS; NUCLEON REACTIONS; RADIATION DETECTORS; RADIATIONS; SEMICONDUCTOR DETECTORS; SPECTRA; STRUCTURAL MODELS
Optional Information
- Notes
- (c) 2015 American Association of Physicists in Medicine