Published February 2017
| Version v1
Journal article
Integration and testing of the DAQ system for the CMS Phase 1 pixel upgrade
Description
The CMS pixel detector phase 1 upgrade in 2017 requires an upgraded data acquisition (DAQ) system to accept higher data rates. A new DAQ system has been developed based on a combination of custom and standard μTCA parts. Custom mezzanines on FC7 AMCs [1] provide a front-end driver for readout, and a front-end controller for configuration, clock and trigger. The DAQ system is undergoing a series of integration tests including readout of the pilot pixel detector already installed in CMS, checkout of the phase 1 detector during its assembly, and testing with the CMS central DAQ. This paper describes the DAQ system, integration tests and results, and an outline of the activities up to commissioning the final system at CMS in 2017.
Availability note (English)
Available from http://dx.doi.org/10.1088/1748-0221/12/02/C02078Additional details
Identifiers
Publishing Information
- Journal Title
- Journal of Instrumentation
- Journal Volume
- 12
- Journal Issue
- 02
- Journal Page Range
- p. C02078
- ISSN
- 1748-0221
INIS
- Country of Publication
- United Kingdom
- Country of Input or Organization
- International Atomic Energy Agency (IAEA)
- INIS RN
- 49019918
- Subject category
- S46: INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY;
- Descriptors DEI
- CMS DETECTOR; COMMISSIONING; DATA ACQUISITION; DATA ACQUISITION SYSTEMS; READOUT SYSTEMS; TESTING
- Descriptors DEC
- DATA PROCESSING; MEASURING INSTRUMENTS; PROCESSING; RADIATION DETECTORS