Analysis of lifting beam and redesigned lifting lugs for 241-AZ-01A decant pump

Description

This supporting document details calculations for the proper design of a lifting beam and redesigned lifting lugs for the 241AZO1A decant pump. This design is in accordance with Standard Architectural-Civil Design Criteria, Design Loads for Facilities (DOE-RL 1989) and is safety class three. The design and fabrication is in accordance with American Institute of Steel Construction, Manual of Steel Construction, (AISC, 1989) and the Hanford Hoisting and Rigging Manual (DOE-RL 1993)

Availability note (English)

MF available from INIS under the Report Number; Also available from OSTI as DE95005433; NTIS; US Govt. Printing Office Dep.