Published April 27, 2006 | Version v1
Journal article

Pressure Rise Analysis When Hydrogen Leak from a Cracked Pipe in the Cryogenic Hydrogen System in J-PARC

  • 1. Japan Atomic Energy Research Institute, Tokai, Ibaraki, 319-1195 (Japan)

Description

As one of the main experimental facilities in the Japan Proton Accelerator Research Complex (J-PARC), an intense spallation neutron source (JSNS) driven by a 1 MW proton beam is being constructed. Cryogenic hydrogen at supercritical pressure is selected as a moderator. The total nuclear heating at the moderators is estimated to be a 3.7 kW. A hydrogen system to cool the moderators has been designed. The most severe off-normal event for the cryogenic hydrogen system is considered to be a hydrogen leak when a pipe cracks. In such a case, the hydrogen must be discharged to atmosphere quickly and safely. An analytical code that simulates the pressure change during a hydrogen leak was developed. A pressure rise analysis for various sized cracks was performed, and the required sizes for relief devices were determined. A safety valve size is φ42.7 mm and a rupture disc for vacuum layer should have a diameter of 37.1 mm, respectively

Additional details

Identifiers

Publishing Information

Journal Title
AIP Conference Proceedings
Journal Volume
823
Journal Issue
1
Journal Page Range
p. 753-760
ISSN
0094-243X
CODEN
APCPCS

Conference

Title
Cryogenic engineering conference
Dates
29 Aug - 2 Sep 2005
Place
Keystone, CO (United States)

Optional Information

Notes
(c) 2006 American Institute of Physics