Refractory brick density by gamma ray transmission

Description

Transmission of 241Am gamma radiation was used to measure the density of refractory bricks. The transmission was proportional to the density provided the radiation path lengths were constant; special holders were used to compensate for small differences in the sizes of the bricks. A 5% density change gave a 15% change in transmission. The method could be used to test several thousand bricks per day. (auth.)

Availability note (English)

MF available from INIS under the Report Number.

Files

8335086.pdf

Files (469.8 kB)

Name Size Download all
md5:df5ec0d252a832bf249242cd9f46b8e0
469.8 kB Preview Download

Additional details

Publishing Information

Imprint Pagination
13 p.
Report number
INS-R--174