Published August 1990 | Version v1
Journal article

Efficiency of hot water accumulator using at NPPs with the WWER type reactors when they are taking part in electric load schedule control

  • 1. Moskovskij Ehnergeticheskij Inst., Moscow (USSR)

Description

Prospects of using hot water accumulators (HWA) at NPPs with WWER type reactors operating under conditions of load schedule varying are analyzed. The thermal diagram of a NPP with high-pressure HWA is presented. This is advisable to be used for generating additional peak power up to 200 MW maximum at a NPP with the K-1000-1500/60-2 turbine. It is shown that additional peak load is equal to 60-130 MW when using HWA with accumulated water temperature of 130-180 deg C

Additional details

Additional titles

Original title (Russian)
Эффективность применения аккумуляторов горячей воды на АЭС с реактором типа ВВЭР при участии их в регулировании графика электрической нагрузки

Publishing Information

Journal Title
Ehlektricheskie Stantsii
Journal Issue
no.8
Series
Ehlektr. Stn.
ISSN
0013-5372
CODEN