Measurement of HTO-HT in atmosphere using the Draeger (Drager) tube

  • 1. University of Surrey, Guildford (United Kingdom)

Description

It is clearly that, incorporation with the liquid scintillation counting, the Drager tube measuring system for Hydrogen allows the measurement of tritium contamination in atmosphere, e.g. HTO/HT (tritiated water vapour/tritium gas) simultaneously, at levels well below those derived air concentrations (DACs) prescribed by The International Commission on Radiological Protection (ICRP) and the UK Regulations. The novel tritium measuring system of Drager tube, in liquid phase or gel phase, can be used as a cheap, convenient and quick method of tritium detection

Files

26071094.pdf

Files (124.6 kB)

Name Size Download all
md5:c6c3687e115fb3dde914f6d1d482ff2e
124.6 kB Preview Download
Part of:
Proceedings of Asia congress on radiation protection

Additional details

Publishing Information

Imprint Title
Proceedings of Asia congress on radiation protection
Imprint Pagination
751 p.
Journal Page Range
p. 231-234.
Report number
INIS-mf--14607

Conference

Title
Asia congress on radiation protection.
Dates
18-22 Oct 1993.
Place
Beijing (China).