Shielding calculations for the TFTR neutral beam injectors

Description

Two-dimensional discrete ordinates calculations have been performed to determine the location and thickness of concrete shielding around the Tokamak Fusion Test Reactor (TFTR) neutral beam injectors. Two sets of calculations were performed: one to determine the dose equivalent rate on the roof and walls of the test cell building when no injectors are present, and one to determine the contribution to the dose equivalent rate at these locations from radiation streaming through the injection duct. Shielding the side and rear of the neutral beam injector with 0.305 and 0.61 m of concrete, respectively, and lining the inside of the test cell wall with an additional layer of concrete having a thickness of 0.305 m and a height above the axis of deuteron injection of 3.10 m are sufficient to maintain the biological dose equivalent rate outside the test cell to approx. 1 mrem/DT pulse

Availability note (English)

MF available from INIS under the Report Number; Available from NTIS, PC A03/MF A01.

Files

10492817.pdf

Files (517.8 kB)

Name Size Download all
md5:65c82ae4114ae9df56e3bfe06c319fe2
517.8 kB Preview Download

Additional details

Publishing Information

Imprint Pagination
31 p.
Report number
ORNL/TM--6949

INIS

Country of Publication
United States
Country of Input or Organization
United States
INIS RN
10492817
Subject category
S70: PLASMA PHYSICS AND FUSION TECHNOLOGY;
Descriptors DEI
ATOMIC BEAM SOURCES; CONCRETES; DISCRETE ORDINATE METHOD; SHIELDING; TFTR DEVICE; TWO-DIMENSIONAL CALCULATIONS
Descriptors DEC
BUILDING MATERIALS; CLOSED PLASMA DEVICES; THERMONUCLEAR DEVICES; TOKAMAK DEVICES