Comparison of ionic and non-ionic nitroxide spin labels for urographic enhancement in magnetic resonance imaging

  • 1. California Univ., San Francisco (USA). Contrast Media Lab.
  • 2. Hopital Cardio-Vasculaire et Pneumologique de Lyon, 69 (France)
  • 3. Bern Univ. (Switzerland). Abt. fuer Radiologie
  • 4. Turku Univ. (Finland). Dept. of Diagnostic Radiology
  • 5. Turku Univ. (Finland). Dept. of Physiology
  • 6. Tuebingen Univ. (Germany, F.R.). Medizinisches Strahleninstitut und Roentgenabteilung

Description

Two nitroxide spin labels (NSL) were compared for in vitro relaxivity and in normal rats for efficiency of urographic enhancement. One of the NSL, PCA, a pyrrolidinyl agent, was ionic and one, NAT, was a non-ionic pyrrolidinyl NSL with multiple hydroxyl substituents for water solubility. Using both NSLs the renal medulla and papilla were noted to show greater contrast enhancement than the cortex, with a maximum enhancing effect between 5 and 15 minutes. Using doses of 1.0 and 2.5 mmol/kg, more than 100% increases in spin echo intensities above the baseline were observed. The lowest tested dose of 0.1 mmol/kg showed an easily detectable enhancing effect for NAT. The good contrast enhancing properties of NAT, considered together with its better acute tolerance, justifies further investigation of this non-ionic compound. (orig.)

Additional details

Publishing Information

Journal Title
Acta Radiol.
Journal Volume
28
Journal Issue
5
Series
Acta Radiol.
Journal Page Range
593-600
ISSN
0284-1851
CODEN
ACRAE

Optional Information

Contract/Grant/Project number
Contract RO1 AM31 937