Published September 2004 | Version v1
Report Open

Development of CANDU fuel in-bay inspection and dimensional measurement system

Description

In this report, we describe a spent fuel inspection and dimensional measuring system for CANDU fuel bundles in atmosphere or water. The submissible camera with radiation resistance was used to inspect a spent fuel in water. The design criteria of the dimensional measuring system was set up ±0.01mm(10μm) for measuring accuracy. The LVDT (Linear Variable Differential Transformer) was used as measuring sensor in this dimensional measuring system. An LVDT calibration equipment was developed in order to satisfy the required accuracy of the system. Also, aluminum master and CANDU Master with same dimension of fuel bundle was made to calibrate the mechanical error of the dimensional measuring system. The accuracy of the fuel inspection system was examined. The results show that the accuracy in dimensional measurement of fuel rod profile and bearing pad profile, diameter of fuel bundle, fuel rod length, and end plate profile using standard test equipment satisfies the design criteria, i.e., maximum measurement error of ±0.01mm(10μm)

Availability note (English)

Available from INIS in electronic form; Also available from Korea Atomic Energy Research Institute, Taejon (Korea, Republic of)

Files

36095421.pdf

Files (10.0 MB)

Name Size Download all
md5:0ffa64f08600722800725a1c00cb4590
10.0 MB Preview Download

Additional details

Publishing Information

Imprint Pagination
122 p.
Report number
KAERI/TR--2819/2004

Optional Information

Notes
39 figs, 24 tabs