Description

Error harmonics are detected using slowly rotating search-coil arrays feeding a digital integrator. The fundamental signal is detected during the first rotational cycle. The search-coil arrays are reconfigured to ''buck'' the fundamental and lower harmonics during the second rotational cycle, allowing the measurement of higher harmonics with excellent resolution. Data are first drift corrected, then harmonic analyzed using the fast Fourier transform technique. The measurements, data processing, and generation of both tabular and graphic output require about 80 seconds. Data are later postprocessed using spreadsheets allowing easy manipulation and comparison or measurements during a test series and between magnets. Hardware and software are described. Accuracy, precision, and resolution are discussed, and the measurement technique for Superconducting Super Collider (SSC) model magnets are described

Additional details

Publishing Information

Publisher
IEEE Service Center.
Imprint Place
Piscataway, NJ (USA)
Imprint Title
Proceedings of the 1987 IEEE particle accelerator conference: Accelerator engineering and technology
Imprint Pagination
2030 p.
Journal Page Range
p. 1573-1575.

Conference

Title
Particle accelerator conference.
Dates
16-19 Mar 1987.
Place
Washington, DC (USA).

Optional Information

Secondary number(s)
CONF-870302--.