This paper presents the work of constructing Chinese reference human voxel phantoms, taking Chinese reference adult female voxel model for example. In this study, a site-specific skeleton structure was built, some radiation sensitive organs were supplemented. Organ sub-segmentation was taken into account. The constructed phantoms include almost all radiation sensitive organs required by ICRP new recommendation. Masses of the organs are almost consistent with the Chinese reference data within 5%. The Chinese reference human phantoms have been applied both in internal dosimetry and external dosimetry. The results provide fundamental data for Chinese radiation dosimetry. In addition, the newly established detailed breast model and micro-bone model were introduced. (authors)

Additional details

Publishing Information

Journal Title
Radiation Protection (Taiyuan)
Journal Volume
34
Journal Issue
4
Journal Page Range
p. 199-205
ISSN
1000-8187

INIS

Optional Information

Notes
7 figs., 1 tab., 16 refs.