Published June 1979 | Version v1
Report Open

Natural circulation steam generator model for optimal steam generator water level control

Description

Several authors have cited the control of steam generator water level as an important problem in the operation of pressurized water reactor plants. In this paper problems associated with steam generator water level control are identified, and advantages of modern estimation and control theory in dealing with these problems are discussed. A new state variable steam generator model and preliminary verification results using data from the loss of fluid test (LOFT) plant are also presented

Availability note (English)

MF available from INIS under the Report Number; Available from NTIS., PC A02/MF A01.

Files

11514324.pdf

Files (162.3 kB)

Name Size Download all
md5:04b8ffb5fbee5faa20a2c68eab79dc02
162.3 kB Preview Download

Additional details

Publishing Information

Imprint Pagination
7 p.
Report number
CONF-791103--30

Conference

Title
American Nuclear Society meeting.
Dates
12 - 16 Nov 1979.
Place
San Francisco, CA, USA.

INIS

Country of Publication
United States
Country of Input or Organization
United States
INIS RN
11514324
Subject category
S21: SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS;
Resource subtype / Literary indicator
Conference
Descriptors DEI
CONTROL SYSTEMS; FEEDWATER; HYDRODYNAMICS; LEVELS; LOFT REACTOR; STEAM GENERATORS
Descriptors DEC
BOILERS; FLUID MECHANICS; HYDROGEN COMPOUNDS; MECHANICS; OXYGEN COMPOUNDS; PWR TYPE REACTORS; REACTORS; RESEARCH AND TEST REACTORS; TANK TYPE REACTORS; TEST REACTORS; VAPOR GENERATORS; WATER; WATER COOLED REACTORS; WATER MODERATED REACTORS