Combination TLD/TED dose assessment

Description

During the early 1980s, an appraisal of dosimetry programs at US Department of Energy (DOE) facilities identified a significant weakness in dose assessment in fast neutron environments. Basing neutron dose equivalent on thermoluminescence dosimeters (TLDS) was not entirely satisfactory for environments that had not been well characterized. In most operational situations, the dosimeters overrespond to neutrons, and this overresponse could be further exaggerated with changes in the neutron quality factor (Q). Because TLDs are energy dependent with an excellent response to thermal and low-energy neutrons but a weak response to fast neutrons, calibrating the dosimetry system to account for mixed and moderated neutron energy fields is a difficult and seldom satisfactory exercise. To increase the detection of fast neutrons and help improve the accuracy of dose equivalent determinations, a combination dosimeter was developed using TLDs to detect thermal and low-energy neutrons and a track-etch detector (TED) to detect fast neutrons. By combining the albedo energy response function of the TLDs with the track detector elements, the dosimeter can nearly match the fluence-to-dose equivalent conversion curve. The polymer CR-39 has neutron detection characteristics superior to other materials tested. The CR-39 track detector is beta and gamma insensitive and does not require backscatter (albedo) from the body to detect the exposure. As part of DOE's Personnel Neutron and Upgrade Program, we have been developing a R-39 track detector over the past decade to address detection and measurement of fast neutrons. Using CR-39 TEDs in combination with TLDs will now allow us to detect the wide spectrum of occupational neutron energies and assign dose equivalents much more confidently

Availability note (English)

MF available from INIS under the Report Number; OSTI as DE93008257; NTIS; INIS; US Govt. Printing Office Dep.

Files

24059716.pdf

Files (434.9 kB)

Name Size Download all
md5:52cd62ed4e1be5611a9d169faada2ed0
434.9 kB Preview Download

Additional details

Publishing Information

Imprint Pagination
8 p.
Report number
PNL-SA--19375

Conference

Title
Harshaw/quality systems (QS) 1992 thermoluminescent dosimetry (TLD) user symposium.
Dates
9-13 Nov 1992.
Place
San Antonio, TX (United States).

Optional Information

Contract/Grant/Project number
Contract AC06-76RL01830
Funding organization
USDOE, Washington, DC (United States).
Secondary number(s)
CONF-9211124--7.