Published 2007
| Version v1
Miscellaneous
Shielding calculation of a Duct Structure in the Industrial 10 MeV-Electron Irradiation Facility
- 1. Ulsan University, Ulsan (Korea, Republic of)
- 2. POSTECH, Pohang (Korea, Republic of)
Description
Industrial facility irradiating a 10 MeV, 30 kW electron beam on a metal target, was designed and the biological shield of the target station were investigated with the evaluations using the MCNPX code simulation. Neutron and photon fluences at each detector positions in the duct were calculated and those are compared with the results of DUCT-III design code calculation. By converting the fluences to the effective dose in a phantom, the user's safety was demonstrated
Additional details
Publishing Information
- Publisher
- KNS
- Imprint Place
- Daejeon (Korea, Republic of)
- Imprint Title
- Proceedings of the KNS spring meeting
- Imprint Pagination
- [1 CD-ROM]
- Journal Page Range
- [2 p.]
Conference
- Title
- 2007 spring meeting of the KNS
- Dates
- 10-11 May 2007
- Place
- Jeju (Korea, Republic of)
INIS
- Country of Publication
- Korea, Republic of
- Country of Input or Organization
- Korea, Republic of
- INIS RN
- 38113545
- Subject category
- S61: RADIATION PROTECTION AND DOSIMETRY;
- Resource subtype / Literary indicator
- Conference, Non-conventional Literature
- Descriptors DEI
- COMPUTER CALCULATIONS; COMPUTERIZED SIMULATION; DESIGN; DUCTS; ELECTRON BEAMS; M CODES; NEUTRON FLUENCE; SAFETY; SHIELDING
- Descriptors DEC
- BEAMS; COMPUTER CODES; LEPTON BEAMS; PARTICLE BEAMS; SIMULATION
Optional Information
- Notes
- 4 refs, 4 figs