Development of a technique for MRI gold-standard direct volumetric measurement of complex joint effusion, and validation at the hip
Creators
- 1. Department of Radiology, University of Alberta Hospital & Stollery Children's Hospital, 2J2.00 WC Mackenzie Health Sciences Centre, University of Alberta, Edmonton, AB (Canada)
- 2. Department of Physical Therapy, Faculty of Rehabilitation Medicine, University of Alberta, Edmonton, AB (Canada)
- 3. Central Alberta Medical Imaging Services, Red Deer, AB (Canada)
- 4. Medical Imaging Consultants, Edmonton, AB (Canada)
Description
Accurate joint fluid quantification on MRI cannot simply rely on measuring the maximum fluid depth or using an ellipsoid approximation as this does not fully characterize the complex shape of a fluid-filled joint. As per the Outcome Measurement in Rheumatology (OMERACT) filter, we sought to evaluate the feasibility, reliability, and validity of a semi-automated supervised technique to quantify hip effusion volume. Ninety-three hip osteoarthritis patients were imaged with coronal short TI inversion recovery (STIR) and sagittal intermediate weighted fat-suppressed (IWFS) sequences at two time points (Fig. 1). Volumetric quantitative measurement (VQM) of joint fluid and measurement of the largest femoral neck fluid thickness (FTM) was performed using the custom MATLAB software. Self-reported Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) and clinical measures of pain, stiffness, and function were recorded. Inter-observer reliability was significantly higher for VQM than FTM (ICC = 0.96 vs. 0.85, p < 0.05). VQM and FTM correlated moderately (r = 0.76, p < 0.0001). There was significantly more articular fluid in symptomatic than asymptomatic hips at baseline (mean = 9.8 vs. 5.9 mL). Volumetric quantitative measurement generally displayed more frequent and stronger correlations to clinical parameters than FTM. Volumetric quantitative measurement required 3.9 min/hip vs. < 1 min/hip for femoral neck fluid thickness. Volumetric quantitative measurement of joint effusion can serve as an MRI gold-standard, could apply to other joints and collections, and is highly suited to future automation.
Availability note (English)
Available from: http://dx.doi.org/10.1007/s00256-020-03630-6Additional details
Identifiers
Publishing Information
- Journal Title
- Skeletal Radiology
- Journal Volume
- 50
- Journal Issue
- 4
- Journal Page Range
- p. 781-787
- ISSN
- 0364-2348
- CODEN
- SKRADI
INIS
- Country of Publication
- Germany
- Country of Input or Organization
- Germany
- INIS RN
- 52059988
- Subject category
- S62: RADIOLOGY AND NUCLEAR MEDICINE;
- Descriptors DEI
- AUTOMATION; BODY FLUIDS; BONE JOINTS; COMPUTER CODES; CORRELATIONS; FEASIBILITY STUDIES; FEMUR; IMAGE PROCESSING; INFLAMMATION; INJECTION; NMR IMAGING; PAIN; PELVIS; RELAXATION TIME; RELIABILITY; RHEUMATIC DISEASES; STEROIDS; VALIDATION; WEIGHTING FUNCTIONS
- Descriptors DEC
- BIOLOGICAL MATERIALS; BODY; DIAGNOSTIC TECHNIQUES; DISEASES; FUNCTIONS; INTAKE; MATERIALS; ORGANIC COMPOUNDS; ORGANS; PATHOLOGICAL CHANGES; PROCESSING; SKELETON; SYMPTOMS; TESTING