Published April 2021 | Version v1
Journal article

Evaluation of neutron spectra and dose equivalent from a Varian 2100C/D Medical Linear Accelerator: Monte Carlo simulation and a literature review

  • 1. University of Birjand, Physics Department, Faculty of Sciences, 9717851367 Birjand (Iran, Islamic Republic of)

Description

In this study was carried out a review according to experimental and Monte Carlo studies in the literature on the neutron production from 18 MV, Varian 2100C/D linac. The effects of these neutrons were investigated on the total fluence, the energy spectra, and the dose equivalent. These factors were calculated as a function of depth and the radiation field size by simulation of linac head using of MCNPX2.6.0 code. The neutron strength was found equal to 1.23 x 1012 nGy-1.The results showed that with increasing the field size from 5 x 5 to 40 x 40 cm2, the neutron fluence and dose equivalent in the water phantom rose to the maximum value for 25 x 25 cm2 field (3.05 x 107 ncm-2Gy-1 and 3.14mSvGy-1 respectively) and then decreased with increasing the field size. According to the results, the magnetite-steel, ordinary, and limonite-steel concrete walls significantly increased the neutron dose equivalent for about 27.4%, 17.2%, and 13.5%, respectively. (authors)

Availability note (English)

Available from doi: http://dx.doi.org/10.1051/radiopro/2021002

Additional details

Identifiers

Publishing Information

Journal Title
Radioprotection
Journal Volume
56
Journal Issue
no.2
Journal Page Range
p. 93-101
ISSN
0033-8451

Optional Information

Notes
52 refs.