Published August 2019 | Version v1
Journal article

Analysis and solution of tripping function failure of fuel assembly gripper

Creators

  • 1. Nuclear Power Operation Management Co., Ltd., CNNP, Haiyan (China)

Description

Gripping device is a core part of the refueling machine, its reliability has great significance for the safety and stability of refueling operation. Unable tripping failure has a certain impact on refueling operation. With the gripping device of Qinshan nuclear power plant as the target, the failure phenomenon was described, combined with the maintenance experience. The reasons of key component defect were analyzed in detail, the troubleshooting methods were summarized to provide reference for similar failure. (author)

Additional details

Identifiers

Publishing Information

Journal Title
China Nuclear Power
Journal Volume
12
Journal Issue
4
Journal Page Range
p. 410-414
ISSN
1674-1617

Optional Information

Notes
4 figs., 1 tab., 2 refs.; http://dx.doi.org/10.12058/zghd.2019.04.410