Analysis and solution of tripping function failure of fuel assembly gripper
Description
Gripping device is a core part of the refueling machine, its reliability has great significance for the safety and stability of refueling operation. Unable tripping failure has a certain impact on refueling operation. With the gripping device of Qinshan nuclear power plant as the target, the failure phenomenon was described, combined with the maintenance experience. The reasons of key component defect were analyzed in detail, the troubleshooting methods were summarized to provide reference for similar failure. (author)
Additional details
Identifiers
Publishing Information
- Journal Title
- China Nuclear Power
- Journal Volume
- 12
- Journal Issue
- 4
- Journal Page Range
- p. 410-414
- ISSN
- 1674-1617
INIS
- Country of Publication
- China
- Country of Input or Organization
- China
- INIS RN
- 54110748
- Subject category
- S22: GENERAL STUDIES OF NUCLEAR REACTORS;
- Descriptors DEI
- DEFECTS; FAILURES; FANGJIASHAN-1 REACTOR; FUEL ASSEMBLIES; GRABS; MAINTENANCE; NUCLEAR POWER PLANTS; REACTOR CHARGING MACHINES; RELIABILITY; SAFETY
- Descriptors DEC
- ENRICHED URANIUM REACTORS; EQUIPMENT; MATERIALS HANDLING EQUIPMENT; NUCLEAR FACILITIES; POWER PLANTS; POWER REACTORS; PWR TYPE REACTORS; REACTOR COMPONENTS; REACTORS; THERMAL POWER PLANTS; THERMAL REACTORS; WATER COOLED REACTORS; WATER MODERATED REACTORS
Optional Information
- Notes
- 4 figs., 1 tab., 2 refs.; http://dx.doi.org/10.12058/zghd.2019.04.410